Anschlüsse Flansche EN1092 PN10/16/40
(abhängig von Nennweiten)
Nenndruck PN16 (ab DN300 max. PN10)
Größen DN50 - DN600
Dichtungen EPDM, FPM (Viton), NBR
Temperatur -10° T +90°C (NBR),
-10° T +120°C (EPDM)
-10° T +150°C (FPM)
-10° T +200°C (PTFE)
-10° T +300°C (Metallisch)
Baulänge

EN558-1 Reihe 16

Check valve for mounting between flanges

ACG double wing check valves stand out for their simple construction and their short construction lengths (pursuant to DIN EN 558-1, row 16). They can be directly installed between DIN flanges (PN 10, PN 16).

ACG double wing check valves require a low opening pressure. The opening force emerging from this deflects the wing against the spring and the weight of the wing so that the medium is released.

If the output pressure exceeds the input pressure, the disc shuts and seals off against the medium through the O-ring.

ACG double wing check valves are maintenance free. 

RSK

Rückschlagklappen - Check valves - Valvole ritegno.pdf 0